RESTAURANT EQUIPMENT PARTS - FREE SHIPPING WITHIN THE USA*

SRH77A-ONLY-E-TEMPERATURE-HUMIDITY-METER-WITHOUT-PROBES

SRH77A-ONLY-E Temperature & Humidity Meter without probes

SRH77A-ONLY


Brand New, Factory Fresh - Includes Full Factory Warranty

The Cooper-Atkins SRH77A is a feature packed meter that consistently beats out the competition. The 2 temperature probes sold with the full version and the RH probe are not included with this "ONLY" version. The electronics are built into a rugged case. Temperature range is -40/300F (-40/150C). RH range is 10/95%. Special features include Wet Bulb, F/C, Backlight, Temperature Differential, Scan Mode and Auto Shut-off. The SRH77A is a Value Priced Workhorse!


Specifications


While the temperature probes can be used to a maximum of 300 degrees, the humidity probe should not be used above 150 degrees F. Temperatures over 150 degrees F will damage the humidity probe. Further, if used in an environment which is smoky or where contaminants are present, the humidity probe will likely be damaged. Probes that are used under any of these conditions can not be warranted.

If you have a high temperature/high humidity application, please call our Applications Engineers at 800-390-0004 x1002. The most cost effective way to determine relative humidity at high temperatures is usually to use the Wet Bulb/Dry Bulb method. Call for details.

  • Backlight Backlight display
  • Certifications CE, RoHS, NIST, WEEE
  • Temperature Diff Temperature differential between zones 1 & 2
  • Case Rugged Hard Carrying Case
  • Auto Shut-off after 15 minutes of non-use or continuous ON mode
  • Humidity 10 to 95% RH, 90% non-condensing
  • RH % RH and Wet Bulb
  • Zones 3 Zones
  • Switchable °F/ °C Yes
  • Memory Min / Max memory
  • Warranty 5 Year Instrument Warranty, 1 Year Probe
  • Calibration Factory Calibrated
  • Keypad Sealed Keypad which protects instrument from spills & dust
  • Temperature Range -40 ° to 300 °F ( -40 to 150 °C) **300 degree is an absolute maximum temperature. The thermister sensor will be destroyed is exposed to temperatures over 300 degrees.
  • Temperature Accuracy ±0.3 °F or ±0.5% Reading, whichever is greater
  • Resolution 0.1 °, 1% RH
  • Weight 1lb 5oz (595g)
  • Dimensions 9.5" x 6.5" x 3.5" (241 mm x 165 mm x 89 mm)
  • Battery Type (1) 9Volt Alkaline
  • Battery Life 90 hours

 

Optional Probes

(Not included with this "ONLY" version are: Model 1075 General Purpose Probe, 4011 Surface Probe, 5028 Humidity Probe The hard carrying/storage case and (1) 9V battery are included.


Optional Accessories:
10' (3.1 m) extension cable, Model 9010 / 50' (15.2 m) extension cable, Model 9015
Battery eliminator, 9 VDC 100 MA regulated, Model 9317
Click on this line to see other probes for this instrument.


Notes

Between 20 and 80 percent relative humidity, the accuracy is +/- 2%, and below 20 percent or above 80 percent relative humidity, the accuracy is +/- 3%.

While the temperature probes can be used to a maximum of 300 degrees, the humidity probe should not be used above 150 degrees F. Temperatures over 150 degrees F will likely damage the humidity probe.

If you have a high temperature/high humidity application, please call our Applications Engineers at 800-390-0004 x1002. The most cost effective way to determine relative humidity at high temperatures is to use the Wet Bulb/Dry Bulb method. Call for details.

Tech Instrumentation